ARISTONCAVI - Homepage
Wednesday 7 January 2009
winding reel cable
 

URSUS © 0,6/1 kV /NSHTÖU 0/J


URSUS 0,6/1 kV /NSHTÖU 0/J


npi oh hag ams 

coding
resistances

approved VDE 0250 part 814

1
Conductor: flexible tinned copper

2
Insulation: EPR base compound (VDE 0207)

3
Inner sheath: rubber GM1b grade (VDE 0207)

4
Textile antitwisting braid

5
Outer sheath: special polychloroprene
base compound (VDE 0207)

6
Outer sheath:
Polychloroprene EM2 grade (VDE 0207)

 

 

  
 technical data
 

Nominal voltage: 0.6/1 kV

Test voltage in CA: 4 Kv

Max conductor temperature: 90°C

Max short circuit temperature: 250°C

Min. ambient temperature: -20°C

Min. bending radius (mobile laying): VDE 0298-3

Max torsion strength: +/-25°/m

Max working speed: 120 m/min


NORME DI RIFERIMENTO:VDE 0250-814

 

 

  
 Description and applications
 

Power and signalling cable for mobile connections, designed for high mechanical stresses tensile strength and torsion), for heavy duty conditions: all weather conditions, abrasion and crushing. The cable is typically used in winding drums for harbour cranes, container cranes, conveyors, handling machines, conveyors, handling machines and mining & tunnelling equipment. For the stresses evaluation all the involved parameters must be taken into consideration: speed, reeling and unreeling time (with the relevant acceleration), minimum bending radius, torsion stress.
The -K version is suitable for temperature up to -40C°.

The NSHTOU VS 0,6/ KV is olso availabe, for heavier conditions such as vertical tensile strength and higher reeling speed.


Download PDF

 

 

  
 dimensional features
 

 

 

 

 

 

  
aristoncavi 36040 BRENDOLA (VI) Italy - Via Einaudi, 8 - Tel. +39 0444 749900 Fax +39 0444 749800  P.IVA:02779180245 info@aristoncavi.com Site required flash pdf